9 m 2 ). Protection against Wind, Seismic and Flood Events. Some form of uplift resistance has always been required. 5A resists both lateral and uplift loads. Tighten the straps using the tensioning device provided with the ground anchors. all aluminum extrusions shall be 6063-t6 alloy with minimum yield strength of fy=31. Jan 25, 2017 · Hurricane Mitigation Retrofit Requirements and/or secondary waterproofing when an existing roof is replaced. 5T resists both lateral and uplift loads. This Guide is intended to help you decide how to protect your home against the winds and rains of hurricanes. The maximum dimension between structural supports shall be 25 feet (7620 mm) in width or 20 feet (6096 mm) in height. Your truss shop drawing will tell you how many pounds up uplift the connection needs to resist. 148" x 1 1/2" minimum nails. 1 in the FBCB permits an existing self-adhered membrane to remain The Product Installer's Guide allows you to view installation instructions for our most common products. Typically, hurricane ties are stainless steel or galvanized steel, as both are strong and will not The S/H2. Truss Jul 20, 2015 · To my knowledge, "hurricane clips", ties or any other specific product have never been required prescriptively. 474. Provides a connection as part of a continuous load path to resist wind and seismic forces. For further clarification or additio. of those edges or corners, but it is best to install hurricane ties or straps on every rafter or truss. The straps must be secured with screws at least 1/4″ x 3″ long and penetrate at least 1. 5A), some are designed so the truss or rafter fits inside a “U” shape design to allow for fastening from both sides (such as the H1). Except the Florida panhandle where the region lies within 1 mile of the coast. Allowable lateral loads are F 1 = 75 lb. 1 When a roof on an existing site-built, single family residential structure is replaced:Roof-de. 5 Lintels 96 304. H3 ties are available in left- and right-hand models and can be installed in pairs. Each clip is 5. The H3 single-sided hurricane tie is designed to resist moderate loads at the rafter/truss-to-top-plate connection. 5 and S/H3 are designed to resist seismic and wind forces in cold-formed steel applications. Also, it is not unusual to have a hurricane or tropical storm outside of hurricane season. Systems 104 306. This is the panel that goes between the roof’s eaves and the walls of the home. 3(1)) and bracing requirements based on seismic design category (see IRC Table R602. 1. The S/H2. Windstorm lengths are available from 97 1/8″ up to 145 1/8″ in 7/16 and 15/32 thickness categories. Single and double-wide mobile homes both require diagonal tie-downs. The H2. these requirements do not apply to the High-Velocity Hurricane Zones (HVHZ). H10A models come with optional fastener holes to connect roof Jan 1, 2021 · Step 1. Flying debris, torrential rain, and gale-force winds can all hurt or even kill people. ) Attach the Hurricane Straps. com. Single-wide homes are more vulnerable to the lateral (sideways) wind forces due to their narrow width, so they also need vertical tie-downs. Jan 10, 2022 · Retrofitting Hurricane straps means adding one or two 16d nails to the existing straps. Approved end-jointed lumber identified by a grade mark conforming to Section R802. What are the dates and items included in the 2024 Florida Disaster Preparedness Sales Tax Holiday? There will be two, separate, two-week holiday periods this year. When a roof or wall gets blown away during a hurricane, it exposes the occupants to the storm’s wrath. They'll Work in Conjunction With Other Preventive Measures. 5A) and offers a higher lateral allowable load, making it a cost effective and higher-performing solution to tie down a rafter roof. gov. 5. The HUD required second egress d. If you have old rusty, corroded pre-1995 attachments whether clips or single wraps they may no longer qualify for the insurance discount and you may qualify after we add new nails only! Energy Conservation. The maximum area of each individual standard-unit panel shall be 250 square feet (23. Use a wrench to tighten the bolts, ensuring they’re snug. Next, attach the hurricane straps to the other 201. 1 A strap may be used to connect the top plate to the top of the wall studs provided these straps are located on the same side of the top plate as the strap connecting the rafter or truss to the top plate. Use caution to avoid over-tensioning the straps as this may pull the trailer off the piers. 4 Shearwalls 94 304. 0105 345 and 346 15C-1. Small rooftop equipment – securing equipment to curbs Secure small roof top equipment such as stacks, exhaust fans and air intakes to resist the wind loads in accordance with one of the following: a. In newer construction, metal straps or metal hurricane ties were added that anchor the trusses or rafters to the top plate and Provides full open-wall cavities that allow for faster and better insulation. “High velocity hurricane zone” of Miami-Dade May 27, 2022 · A mobile home tie-down is connected to the anchor via a hook-up system that lets you adjust the tension. Provides faster installation than using two single-sided ties. Eliminates the gable end hinge point when Windstorm extends beyond the bottom chord. 3 Prescriptive method for gable roofs on a wood frame wall. These U-shaped hurricane ties provide faster installation than using two single-sided ties. Hardboard siding shall conform to the requirements of ANSI A135. The following is a collection of product testing inquiries that helps product and system manufacturers seeking to get their products approved for use in the High Velocity Hurricane Zone (HVHZ). Instalar con un destornillador de casquillo hexagonal o de tuercas de 3/8". 2 m 2 ). Install with 3/8" hex socket or nut driver. 1 Rafters. 844-990-9797. The total cost of damage is estimated at $1. H2. 4487. Ties must be selected based on the load resisted by the connection and the connection type, such as wood truss/ rafter to wall top plate, wood truss/rafter to top plate and wall stud to qualify for single straps or double straps both must wrap over the truss and be nailed with two nails on the front and the third nail on the back of the strap. Contact us today! LGT Restoration Services, LLC is a licensed general contractor that provides professional Truss Mitigation and Hurricane Retrofits to homeowners in Florida. can I use screws to install the straps instead of nails On 2018-08-05 by (mod) - tie downs must meet the Zone II or Zone III requirements Here are the key points regarding hurricane strap retrofitting: Purpose: The primary purpose of hurricane straps (also known as roof tie-downs, seismic straps, or wind straps) is to strengthen the connection between the roof structure and the walls of the building. INFORMATION YOU NEED. A35 Joist to Beam Condition. 1 of the 7th Edition (2020) FBCB and Section R905. Height and area limitations based on type of construction : 7-9 . Use storm shutters or shields to protect inside of shed. If you are securing it directly into concrete, use 1/4-inch expansion bolts in place of the screws. ) SIMPSON Strong-Tie Many of these products are approved for installation with Strong-Driveœ SD Connector scre_vs. R802. THE WIND. 1. When properly installed, tie-down clips can help your AC system survive Category 5 wind speeds. and F 2 = 125 lb. A new exception to Section1507. The H8 single-sided hurricane tie is designed to resist moderate loads at the top of a wall connection. The first begins on Saturday, June 1, 2024, and ends on Friday, June 14, 2024. The maximum area of each thin-unit panel shall be 150 square feet (13. Fire resistance and protection requirements : 10 . Another thing to consider is the wood being attached should also be well matched to the height of the hurricane strap. For more information, see p. For additional details see Section 1507. Free of corrosion. 1 Uplift resistance. Algunos conectores se instalan con el Simpson Strong-Tie Strong-Drive 1/4" SDS HEAVY-DUTY CONNECTOR screw. Materials: See Load Table. 0 ksi unless it is specified. 3 Interior Panels. 1 Photovoltaic panels and modules. 2 Bond Beam 93 304. D. Reference Series: GBC, H, HCP, HS, TSP. For Motor Vehicle Services, the general customer service number is 609-292-6500 or, for the hearing impaired, 609-292-5120. Requirements for evacuation : 11 Specific requirements to allow use and access to a building for persons with disabilities . thirdnailguy@gmail. Pursuant to Section 553. The first step to installing hurricane straps on an existing roof is to remove the soffit on the outside of the house. The first level that receives a worthwhile discount is Clips, also known as “Hurricane Clips," and a photo of Nov 24, 2019 · I have to install new hurricane straps to tie the rafters to the top plate and the wall in zone 3 (port orange FL 32129). CSHP – High-Performance Coiled Strap Installation. Use 5/8-inch (1. 1 shall be permitted to be used interchangeably with solid-sawn Start by placing the strapping at the back of the tank. 4. This information is also intended to help the test laboratories perform the testing in compliance with the HVHZ. These anchors tie trusses and rafters to top plates and may be used to tie wood framing members to resist uplift and lateral forces. 1 billion in 2015 dollars). CS/CMST14 – Coiled Strap Installation. Straps. 2 Ceiling Diaphragm and Gable Endwall Bracing 102. Special requirements for specific occupancies or elements : 5-6 . Step 4: Mark And Count The Spots Where The Trusses Meet The Beams. 1 306 Roof Framing io~ 306. 10. And, it is intended to help you decide what protection measures to take first. VGT – Girder Tiedown Installation. While the majority of the hurricane ties that Simpson Strong-Tie offers are one-sided (such as the H2. The symmetrical design eliminates the need for separate right and left parts. 5T ties are available in left- and right-hand models and can be installed in pairs. Hardboard underlayment shall meet the strength requirements of 7 / 32 -inch (5. A35 Studs to Plate Condition. O. Wherever access makes it possible (without damage of the wall or soffit finishes), both top plate members shall be connected to the stud below using a stud to plate connector with Oct 21, 2009 · Jun 22, 2010. Huge savings for one detail. Nothing is grandfathered. Provides a connection between the truss or rafter and the wall of the structure that helps resist wind and seismic forces. The Medium Twist Straps (MTS) and Heavy Twist Straps (HTS) are used to resist wind uplift and manufactured in lengths of 16″, 20″, 24″ and 28″. 8 billion dollars (or $3. Demand Load - When selecting the proper hurricane strap you need to Technical Bulletin MiTek-US. 6 and, where used structurally, shall be identified by the label of an approved agency. Additional installation information can also be found in the Simpson Strong-Tie Wood Construction Connectors catalog. ” FEMA Grant 1. Building and Construction Product Data, Submittal Tools Oct 2, 2018 · 15C-1and2S. Hurricane Preparedness Guide - Broward County Save money on insurance by calling Roof To Wall Retrofits and having us upgrade your hurricane straps by adding nails to your old attachments. anchors shall be as listed, spaced as shown on details. Roofers use hurricane ties to reinforce the connection between the roof truss and the wall plate. Jul 26, 2018 · See our blog post Is it worth it to upgrade my roof tie-down hurricane straps for a better wind mitigation insurance discount? if you want to improve your roof-to-wall connection for better hurricane-resistance and insurance discount. 5 is made for moderate loads at the rafter/truss, while the S/H3 is made for moderate loads at the rafter/truss-to-top-track cted by persons not certified. No more than 1/2″ spacing from the truss. The H8 is versatile and has been tested for connecting I-joist rafters to double top plates as well as studs to sill plates. ETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES101 Retrofits Required. You can now attach the hurricane straps to the foundation. Build strong walls. Hurricane season begins June 1 and ends November 30. 1 m) in height in any and all structures; Risk Category IV—Essential Facility buildings or structures shall follow the large missile impact testing in Section 1626. Code Reports: View Code Report Table. Oct 16, 2023 · Hurricane straps do an excellent job in both these domains. It is recommended that all straps be tightened only enough to remove the slack. hurricanes. Openings created for access to the addition, are. 1 End-jointed lumber. Roof and rafter hurricane ties, also called hurricane straps or strips, are galvanized or low-carbon steel connectors used to strengthen wood and metal-framed roofs. The bottoms of the clip engage with the top plate via four screws, creating a very secure connection between the roof and walls. It comes in various materials, including vinyl, aluminum, and wood. 6 Masonry Wall Connections 99 304. This is a fully integrated custom code based on the 2018 International Building Code. The IRC does require what is commonly refered to even here in Montana as "Hurricane Clips" My own house equated out to over 500 lbs of uplift in a 90 mph wind load R802. The issue here is, these areas where the roof framing meets the top of walls are usually hidden behind drywall on the Simpson Strong-Tie. Bring it to the front and then take it back to the wall. H1A – Hurricane Tie Installation. or cannot be used or blocked unless another is provided. this product has been designed and tested to comply with the requirements of the florida building code 2017 edition including high velocity hurricane zone (hvhz). C. They shall be approved for connecting wood-to-wood or wood-to-concrete as appropriate. This allows fastening on both sides. 844 553. Mar 31, 1999 · 298 (a) When anchors and straps are used for stabilizing the home in the longitudinal direction the strap must connect to a clip welded onto the I-beam or other device connected mechanically. Straps & Ties. 5A connects the truss/rafter to the top plate and is also suitable for joist to bearer connections. Select Language. 5A single-sided hurricane tie is designed to resist moderate loads at the rafter/truss-to-top-plate connection. 59 cm) anchor bolts for this task. 185 Oregon Department of Consumer and Business Services Building Codes Division P. Secure floor frame to the foundation. H8. Because the outside roof corners get the most stress during high winds, the code requires those locations to be addressed first. Obtaining an inspection generally Sep 19, 2019 · Tie-down clips give your AC system a fighting chance against strong winds. 304. For maintenance issues such as malfunctioning traffi c signals and potholes, direct calls to 1-800-POTHOLE. The H1A provides a connection between the truss or rafter and the wall of the structure that helps resist wind and seismic forces. Wood Construction Connectors H/TSP Seismic and Hurricane Ties (cont. Learn about the importance of hurricane straps Texas Department of Insurance 1601 Congress Avenue, Austin, TX 78701 | PO Box 12030, Austin, TX 78711 | 512-676-6000 | 800-578-4677 1. 6. • Use of other •attachments (plumbing straps) • The current version of the OIR-B1-1802 provides specific minimum nailing requirements; for example, single wraps and Blueprints –Ifnailing pattern details provided Clear photos from a prior retail the inspector is unable to gain attic access or view features, you can: 1512. Insurance Discounts and Credits. Rafter Condition. 1 Ceiling Joists 102 305. In extreme storms, such as Hurricane Andrew, the force of the wind alone can cause weak places in your home to fail. FEMA P-804 (2023) references the criteria for 2020 FORTIFIED Hurricane Home designations (also referred to as the “Basis of Requirements”) for existing homes with some exceptions, which are more conservative and designated as “FEMA Grant Requirements. The first step is to have an inspection of your home. MATERIAL: HA4, HA6 A103. Double-check that all straps are tightly secured and properly aligned. Remove The Soffit Outside Of The House. Secure each strap using appropriate fasteners, such as nails or screws. Installed at all four corners of your AC cabinet, tie-down clips firmly anchor your unit to the concrete pad. org Some connectors install with the Simpson Strong-Tie ® Strong-Drive ® 1/4" SDS HEAVY-DUTY CONNECTOR screw. 25 inches long by 5. “Wind-borne debris region” where design speeds are greater than 120 mph or greater than 110 mph if within 1 mile of the coast. They are metal connectors with holes for fasteners, such as nails or screws. Remove only the amount of foam necessary to perform the installation. This article will explain the requirements for hurricane In lieu of a grade mark, a certificate of inspection issued by a lumber grading or inspection agency meeting the requirements of this section shall be accepted. They make buildings more resistant to the effects of high winds, especially in areas prone to natural disasters. 3 Vertical Reinforcement 93 304. 0107 , 347 F. pdf. The embossments add stiffness in crucial areas for improved H10A. Apr 3, 2024 · Double Strap: Two separate metal pieces that wrap over the wall truss, each secured with three nails, providing even greater stability than a single strap. 348—352 for more information. The bottom strap must be at least 4 inches above the water heater’s controls. To be a Clip or Strap the roof attachments must meet the minimal requirements listed below or the roof to wall connection is considered as Toe Nail or Other The amount of qualifying braced wall length for a particular braced wall line is determined by selecting the greater of the wind and seismic braced wall length requirement as determined by the bracing requirements based on wind speed (see IRC Table R602. Install storm-resistant windows and doors. A Strap must wrap over the truss and be nailed on the opposite side. Ask for information about pro- tecting your family and home. The choice of a hook-up and tension system depends on the type of tie-down you want to install. 11. The H1A is designed for nominal 2x lumber. This plays a The H1. 1 General Requirements 93 304. 5T single-sided hurricane tie is designed to resist moderate loads at the rafter/truss-to-top-plate connection. All homes must be outfitted with these frame-strengthening devices so the structure can withstand high winds. 8 ft. 11 Roof tie-down. 1 for the appropriate maximum basic wind speed and the metal shingle packaging shall bear a label to indicate compliance with ASTM D3161 and the required classification in Table 1504. That means for five of twelve months of every year, Floridians are at risk for exposure to high winds. May be installed on the inside face of the stud. 844, and only sloped hipped or gable roofs are required to comply. Hurricanes can create mighty wind gusts that can easily tear away roofs if they’re not adequately secured. Unless factory installed, the connection device must be approved by the department pursuant to Rules 344 15C-1. Rafter connectors – these are the most common type of hurricane strap. This guide covers hurricane mitigation, insurance topics, alert systems, evacuation information (pet care, evacuation routes, shelter locations), and zoning. The UCC establishes clear and predictable requi. Avoiding Hurricane Damage: A Checklist for Homeowners. 22 kilograms). Hurricane Tie. Our employees live in all the metropolitan areas of Florida, including Miami, Fort Lauderdale, and Tampa. com Customer Service & Technical Assistance Phone: 1-800-328-5934 • Fax: 1-952-898-8605 • Email: USPcustomerservice@mii. As part of a continuous load path, the H3 resists both lateral and uplift loads. 5″ into the wall studs. 201. 4. 12-13, 27-30 • Includes 6 hurricane straps for added security (1” x 6” x 16 GA galvanized G90) • Lightweight and transports easily • Easy assembly • No need for risers or stand-ups • Saves on job completion time • Designed and fabricated in accordance with the requirements of the 2023 Florida Building Code, 8th Edition H1A. to be accomplished by a certified installer or mechanic. They’re made of galvanized steel, and they Download PDF: Shed Anchor Installation Tap or click to enlarge image Securing shed with 3AL-60cc cable clamps PE18 Anchor How anchors go into the ground for sheds Arrowhead installation with drive rod Anchoring options for sheds PE26 with L90 bracket holding a shed in asphalt PE26 attached to shed with PE-L90 bracket Shed Anchor Kit - Aluminum Hurricane designations for existing homes (Figure 3). 486. More information is available in the installation section below. If using the latter, make sure the width of the truss or rafter is suitable for Hurricane T-Shaped Strap. Use the anchor bolts to fasten them from wall studs to the foundation through the sill plate. In older wood frame construction, the connection of roof trusses or rafters to walls is 2 or 3 sixteen penny (16d) nails driven at angles (toe nailed) through the rafter or truss into the top plate of the wall. 25 inches wide with 3/4-inch wide flanges. 7 Interior Walls 101 305 Ceiling Framing 102 305. Only site built single family residences are included in the requirement for mitigation retrofits and/or secondary waterproofing per Florida Statute 553. Straps and tie plates shall be manufactured from galvanized steel with a minimum thickness provided by 20 gauge. ASCE 7-05 using the appropriate basic design wind speed and an Importance Factor of 1. Debris can break windows and doors, allowing high winds inside the home. 101. 2 Partially inaccessible straps: Where part of a strap is inaccessible, if the portion of the strap that is observed is fastened in compliance with these requirements, the inaccessible portion of the strap shall be presumed to comply with these requirements. The vast majority of hurricane straps are one-sided, there is also a U shape design that fits into trust and rafters. Dimensional Requirements. In general, hurricane straps are considered to offer a higher level of protection than hurricane clips, as they provide more surface area for attachment and can withstand stronger winds. The H14 comes with a pre-bent flange that attaches underneath . The hook-up system should be weather- and corrosion-resistant and support at least 4,725 lbs (2,143. Simpson Strong Tie H1 clip is one of the most commonly used. #4. 2. ing attachment and fasteners shall be strengthened and corrected as requi. DEPARTMENT OF CONSUMER and BUSINESS SERVICES BUILDING CODES DIVISION. These products are available with additional corrosion protection. 15 b. Product Testing Inquiries. You will find that many of the retrofits or protective measures are easy to do for a physically fit homeowner. A35 – Framing Angle/Plate Installation. Take a drywall saw and carefully cut the foam away from the bottom plate in the shape of the strap sufficient to allow installation and attachment to the wall framing. The H10A series holds the rafter or truss on both sides for high uplift applications with embossments that add stiffness in crucial areas for improved performance. R607. Hurricane straps make sure that the building stays together. 3. 884, Florida Statutes, strengthening of e. . Human Safety. If so, replace these sections with similar materials of the same thickness. Then, after all the straps are installed and the slack removed, tension the straps. Note: if you have a pothole damage claim you must call 609-984-7294. Whether it’s attic, outside, or inside – now you know where you will install hurricane straps. Ask your emergency manage- ment office, building Apr 18, 2022 · Hurricane Binding Exception The hurricane binding exception rule, as stated in the TWIA Plan of Operatio n, begins after a windstorm is designated as a hurricane by the United States National Weather Service is in the Gulf of Mexico or within the boundaries of 80° west longitude and 20° north latitude and continues until the General Metal roof shingles tested in accordance with ASTM D3161 shall meet the classification requirements of Table 1504. The number of tie-downs required is dependent on Effective April 1, 2010. Mar 18, 2019 · Double straps – 2 metal connectors that wrap over the truss. Finish: G90 galvanizing; HHCP4-TZ – G-185 galvanizing. Authorized by ORS 446. May 10, 2022 · Hunker: How to Calculate Load Bearing Capacity of a Flat Roof. sPlumbingThe Uniform Construction Code (UCC)complete set of technical standards is a for construction with a uniform method of administration and enforcement in order to p. Sep 10, 2023 · Here is a step-by-step guide: Begin by cleaning the roof surface thoroughly to ensure proper adhesion. See pp. The basic steps required to achieve a safer, more wind resistant roof deck are: Remove the old shingles and underlying building paper to expose the roof deck. Timber connectors attach the beams, floor plates, and studs to the structure, while rafter connectors attach rafters to ridge boards. The straps have an offset shape to allow for twisting and bending. Mark these spots, so you remember them later and count them to know how many ties will be necessary when you start working. phone 518. The second holiday period begins on Saturday, August 24, 2024, and ends on Friday, September 6, 2024. As part of a continuous load path, the H2. 6 mm) or 1 / 4 -inch (6. This reinforcement helps prevent the roof from being lifted off or separated floridabuilding. 2 m/s). May 10, 2022 · The two main types of hurricane straps available for sheds are timber and rafter connectors. Utilice el botón "Select Language" para ver el sitio en otros idiomas. But putting in an H clip is an easy way to cover that base in most circumstances. These single-sided hurricane ties form part of a continuous load path for both lateral and uplift loads. These over-the-top straps will be a visible wrap in older single-wides. otect the public's health, safety and welfare. 2. 2010 OREGON MANUFACTURED DWELLING INSTALLATION SPECIALTY CODE. Photovoltaic panels and modules installed on a roof or as an integral part of a roof assembly shall comply with the requirements of this code and the Fire Code of New York State. com January 2019 #USP2557 Twist straps do not need to be wrapped over the truss to achieve the allowable load. To qualify for this discount these connections need to meet a certain criteria: Minimum of 3 nails for clips and straps. Hurricane Protection Requires additional protection from wind-borne debris in: 1. Insurance providers in Florida offer premium discounts to homeowners who take proactive measures to make their homes more wind-resistant. Box 14470 1535 Edgewater Street NW Salem, Oregon 97309-0404 bcd. 3(3)). oregon. The damage to single family residences and contents in the homes totaled $865 million (based on insurance claims made), which is about half of the above figure. This brings up our wind load capacity plus earns the homeowner a good 25% off or more from their premiums. 4073 fax 518. Secure this strapping to the wall studs or the wood block using several 1/4-inch x 3-inch or longer lag screws with oversized washers. hurricane clips and hurricane straps must not have a gap greater than 1/2 inch from the truss or it will be considered as a toe nail. Apr 29, 2022 · The state of Florida has a strict code for hurricane ties and straps. Position the hurricane straps at regular intervals along the trusses or rafters. Protecting Your Home From Hurricane Wind Damage. 4 at 50 feet per second (15. 2 Continuous 5/8-inch or thicker plywood sheathing may be used provided the straps connecting the rafters or Hurricane Retrofit Guide. Jun 3, 2022 · 3. H3 Hurricane Tie. ) Nov 1, 2008 · Homeowners don’t have to spend more than 15% of the total cost of a reroof job on upgrading roof-wall connections. This test shall be applicable to the construction units, assemblies, and materials to be used above 30 feet (9. Key Features. Inspect the roof deck to determine if parts of it are rotted, delaminated, warped or structurally unsound. uring a hurricane, homes may be damaged or destroyed by high winds and high waves. This rugged clip cradles the truss or rafter on two sides. Clips. 1 of the 7th Edition (2020) FBCR. For example, on a $10,000 reroof, if you can’t tie down all the trusses for $1,500 or less, you The best way to build a hurricane-proof storage shed is to start from the bottom, and work your way up using lots of fasteners as you go: Build a hurricane-proof foundation. Hurricane ties are also called hurricane clips and hurricane straps. Use the "Select Language" button to view the site in other languages. 81Z installs with half the nails that are needed for two single-sided twist straps (like the H2. Upon completion of the installation, fill the voids and seal with a foam friendly construction adhesive. Metal plate connectors, straps and anchors shall have product approval. Each strap is 1-1/4″ wide with nail holes (staggered across the width) punched at 1″ along its length. The first seven nail holes on each side of the bend must be filled with 0. Do you know your hurricane risk? Ask your local emergency management office or American Red Cross chapter about the his- tory of hurricanes in your area. A. Select the model from a dropdown list by product category below. 3. when the following installation requirements are met. Adding fasteners to existing straps shall be allowed in lieu of adding a new strap provided the strap is manufactured to accommodate at least 4 fasteners at each end. 4 Metal Plate Connectors, Straps and Anchors. Additional fasteners into the top plates and rafter or truss provide higher uplift. 4 mm) service class hardboard planed or sanded on one side to a uniform thickness of not Nov 9, 2021 · One strap within the top 1/3 of the unit and the second strap within the bottom 1/3. Hurricane Iniki claimed six lives. There are many different types of hurricane ties. H3. hj uj qs aa cv fa ay ux gc sv